This deviation is mainly due to the original records of the measurement and inspection of the water content in the Karl Fischer scale are not separately classified and kept according to the products, and the analyst Lu Qiming did not check one by one according to the quality standard of the intermediate of linezolid when he issued the report, so that when all the test results are not obtained, the output results and the completion time are registered in the sample test account, leading to the analyst Zhang Haijing mistaking the batch of samples The test of all items has been completed, so the moisture test of this batch of samples was not carried out on December 11, 2019. Wang Liying, the reviewer, did not recheck in place, and Bao Haijian, the person in charge of the post, did not carefully check the inspection report in strict accordance with the provisions of h3-sop-61035 workshop material management procedure, which led to the next production of linezolid aromatic amines when the moisture items were not tested. It belongs to human and method reasons.<br>1. On December 15, 2019, IPC tested the water content of 2081-191203 batches of linazolamide aromatic amines, and the water content result was 0.06% (standard: water content ≤ 1.0%). The test result was qualified, meeting the requirements of linazolamide intermediate quality standard, and a new test report was issued based on the result. 2. 2081-191203 batches of linazolamide aromatic amines have been produced to the crude product when the deviation is found. The following process's triphosgene reaction solution, condensation reaction solution, condensation product, hydrazinolysis reaction solution, acetylation reaction solution and crude product detection all meet the quality standard requirements of linazolamide intermediate. The deviation has no effect on the product quality. 3. A total of 10 batches of linezolid were produced in 2018, and 3 batches of linezolid have been produced so far in 2019. All intermediates were tested before the next production, and the results were qualified. 4. For all the inspection reports of Lu Qiming, the screening analyst in the past two years, the inspection report shall be issued after all the items are tested. All the recheck results of the inspection reports of Wang Liying in the past two years were normal. For the intermediates released by the person in charge of the screening post in recent 2 years, all the items are qualified before release.<br>Cp-tz-api-d-tz-api-11li-19001-20001: test the moisture content of 2081-191203 batches of linazolamide aromatic amines. Cp-tz-api-d-tz-api-11li-19001-20002: add moisture test results, correct the report time, and correct the inspection completion time in the sample receiving account in the batch 2081-191203 linazolamide aromatic amine inspection report. Cp-tz-api-d-tz-api-11li-19001-20003: retraining the person in charge of the post, Bao Haijian, on h3-sop-61035 workshop material management procedure and h3-sop-61019 pre production preparation and inspection management procedure, emphasizing the need to carefully check the inspection report according to the quality standard. Cp-tz-api-d-tz-api-11li-19001-20004: the original records of the measurement and inspection of the moisture content of the kappa capacity shall be distinguished separately according to the products. Cp-tz-api-d-tz-api-11li-19001-20005: train analysts Lu Qiming, Wang Liying and Zhang Haijing on h3-sop-61081 management procedure for sample inspection in IPC laboratory, emphasizing that the inspection report shall be issued after the inspection results of all items are obtained and verified by the second person. The review contents include: whether the inspection items are complete, whether the methods used for each item are correct, whether the experimental records are complete and correct, etc.<br>
正在翻译中..